| Frequency Range | 330-520MHz | |
| Uplink | Downlink | |
| Working bandwidth | <5MHz | <5MHz |
| Duplex interval | >4MHz | >4MHz |
| Gain | 50±2dB | 50±2dB |
| Gain adjustment range | 30dB in steps of 1dB | 30dB in steps of 1dB |
| In-band fluctuations | ≤±1.5dB | ≤±1.5dB |
| Output Power | 3dBm | 43dBm (20W) |
| In-band intermodulation attenuation | ≤-40dBc | ≤-40dBc |
| Stray | ≤-36dBm@9KHz~1GHz; ≤-30dBm@1GHz~12.75GHz | / |
| ALC starting control depth | 20dB | 20dB |
| VSWR | <1.5:1 | <1.5:1 |
| Group delay | ≤2.5us near-end and far-end connections tested together | ≤2.5us near-end and far-end connections tested together |
| Noise Figure @ Maximum Gain Test | ≤5dB (tested together with near-end and far-end connections) | / |
| Light wavelength | 1550nm | 1310nm |
| Optical output power | 3dBm | / |
| Maximum optical path loss | 10dB | 10dB |
| Optical connector type | FC/APC or FC/PC | FC/APC or FC/PC |
| Port impedance | 50 Ω | |
| Local monitoring | RS232 | |
| Remote monitoring | Via local GSM SMS modem or Ethernet | |
| powered by | 110VAC or 220V AC(±15%),50~60Hz | |
| Power consumption | ≤120watts | |
| Mean time between failures MTBF | 50,000 hours | |
| IP protection level | IP65 | |
| Heat dissipation method | natural cooling | |
| Operating temperature | -20~+55°C | |
| Working humidity | 0~95%(non-condensing) | |
| Monitoring protocol | Meet China Mobile network management agreement requirements | |
| Mechanical dimensions (length, width, height) | ≤530mm*300mm*200mm | |
Note: The number of remote computers and uplink and downlink frequencies are customized according to customer needs.